Determination of toluene diisocyanate in synthetic-rubber track by ion chromatography with ultraviol Determination of toluene diisocyanate in synthetic-rubber track by ion chromatography with ultraviol

Determination of toluene diisocyanate in synthetic-rubber track by ion chromatography with ultraviol

  • 期刊名字:中国化学快报(英文版)
  • 文件大小:
  • 论文作者:Mei Lan Chen,Yun Chang Fan,Cha
  • 作者单位:Biology and Environment College of Zhejiang Shuren University,Department of Chemistry,School of Economics and Management
  • 更新时间:2023-01-17
  • 下载次数:
论文简介

In the present work,a novel analytical method was proposed for the determination of toluene diisocyanate(TDI)in synthetic-rubber track by ion chromatography(IC)coupled with an ultraviolet detector setting at 212 nm.TDI can be hydrolyzed to toluene diamine(TDA)which can be separated by cation-exchange 1C easily.The optimum IC separation was performed on an IonPac CS 12A colunm(150 mm×4.0 nun)using 20 mmol L-1 sodium sulfate,10 mmol L-1 sulfuric acid and 10% acetonitrile as eluent.It was found that a higher signal response of TDA could be obtained under alkaline condition.A suppressor was used to change the acidic eluent into alkaline one.0.8 mol L-1 potassium hydroxide was chosen as the optimum regeneration eluent.With the added suppressor and regenerant,signal response was magnified by about 16 times and lower limit of detection(LOD,0.13 μg L-1)was obtained,Within-day relative standard deviation(R.S.D.)was less than 3.6%.The recoveries of TDI spiked in synthetic-rubber track samples were 96.4-110.6%.

论文截图
版权:如无特殊注明,文章转载自网络,侵权请联系cnmhg168#163.com删除!文件均为网友上传,仅供研究和学习使用,务必24小时内删除。