In the experiment to determine the plasma electron temperature, a modified multichannel PIN diodes assembly is used as detectors to record the X-ray pulses from a low-energy Mather-type plasma focus device energized by a 32μF, 15 kV (3.6 k J) single capacitor, with deuterium as a filling gas. The ratio of the integrated bremsstrahlung emission transmitting through foils to the total incident flux as a function of foil thickness at various temperatures is obtained for foil absorbers of material. Using 3μm, 6μm, 9μm,12μm,15μm and 18μm thick aluminium absorbers, the transmitted X-ray flux is detected. By comparing the experimental and theoretical curves through a computer program, the plasma electron temperature is determined. Results show that the deuterium focus plasma electron temperature is about 800 eV.
-