Effect of nifekalant on acute electrical remodelling in rapid atrial pacing canine model
- 期刊名字:中华医学杂志(英文版)
- 文件大小:
- 论文作者:TANG Min,ZHANG Shu,SUN Qi,HUA
- 作者单位:Department of Cardiology,Department of Arrhythmia
- 更新时间:2023-02-08
- 下载次数:次
Background Nifekalant may prevent atrial fibrillation (AF) and possibly be useful in treatment of atrial tachyarrhythmia in patients with severe heart failure. This study investigated the electophysiologic effect of nifekalant on the acute atrial remodeling in rapid atrial pacing (RAP) model of canine.Methods Twelve mongrel dogs subjected to rapid stimulation (400 beats/min) at left atrial appendage (LAA)for 24 hours, were randomized into the control group (rapid pacing only, n=6) and the nifekalant group (intravenous nifekalant therapy immediately after RAP, n=6). Atrial electrophysiological parameters were measured in right atrium, coronary sinus, LAA, posterior wall of left atrium (PWLA) and left superior pulmonary vein (LSPV), before and after the RAP.Results In the control group, the effective refractory periods (ERP) were shortened greatly at all sites, paced dogs had substantially shorter ERPs in the high right atrium, LAA, and LSPV, but fewer changes in the PWLA,the coefficient variation of ERP (COV ERP) was increased significantly. After rapid atrial stimulation, the inducibility of AF increased significantly [induction number: pre-RAP vs post-RAP, 1.00± 0.89 vs 8.17 ± 2.79,P<0.01; duration of AF: pre-RAP vs post-RAP, (450.34± 362.59) ms vs (9975.77 ±4376.99) ms, P<0.01]. In the nifekalant group, although the ERPs were prolonged at all sites compared with those in pre-RAP state, only the value at LSPV differed significantly from that in pre-RAP state [pre-RAP vs post-RAP, (102.50±5.24) ms vs (132.51 ±5.20) ms, P<0.01]; the COV ERP did not change statistically in this group. The inducibility of AF slightly increased but insignificantly after pacing [induction number: pre-RAP vs post-RAP, 0.83 ±0.75 vs 1.67±0.82, P=0.19; duration of AF: pre-RAP vs post-RAP, (378.67±317.88) ms vs (1124.08±1109.77) ms,P=0.06]. Conduction time values did not alter significantly in either of the two groups after RAP.Conclusions In canine RAP model, nifekalant inhibited ERP shortening and ERP heterogeneity increasing,decreased AF induction. Nifekalant can reverse acute electrical remodeling effect in this model.
-
C4烯烃制丙烯催化剂 2023-02-08
-
煤基聚乙醇酸技术进展 2023-02-08
-
生物质能的应用工程 2023-02-08
-
我国甲醇工业现状 2023-02-08
-
JB/T 11699-2013 高处作业吊篮安装、拆卸、使用技术规程 2023-02-08
-
石油化工设备腐蚀与防护参考书十本免费下载,绝版珍藏 2023-02-08
-
四喷嘴水煤浆气化炉工业应用情况简介 2023-02-08
-
Lurgi和ICI低压甲醇合成工艺比较 2023-02-08
-
甲醇制芳烃研究进展 2023-02-08
-
精甲醇及MTO级甲醇精馏工艺技术进展 2023-02-08