Strong self-flushing technique for heat exchanger of sewage source heat pump system Strong self-flushing technique for heat exchanger of sewage source heat pump system

Strong self-flushing technique for heat exchanger of sewage source heat pump system

  • 期刊名字:哈尔滨工业大学学报(英文版)
  • 文件大小:
  • 论文作者:XIAO Hong-xia,SUN De-xing,LI X
  • 作者单位:School of Municipal and Environmental Engineering,Architectural and Civil Engineering College
  • 更新时间:2023-02-07
  • 下载次数:
论文简介

To better remove the contamination on the surface of a heat-exchanger in urban sewage source heat pump system (USSHPS), this paper analyzes the feasibility of strong self-flushing on the basis of experiments and presents a new on-line self-flushing technique, which ahemately flushes part of heat transfer tubes, In addition, operation principles and the structure of the new heat-exchanger are introduced and the feasible economical and technological cleaning plans are given by design calculation and scheme comparison. The result showsthat keeping each tube washed for one minute with 5 m/s, the operating cost is lower than (¥)5 and when oneflushing pump alternately flushes 10-20 heat exchangers, the saved costs of flushing 10 tubes alternately are over 4 times of the increased costs.