IEC 61000-4-16-2015电磁兼容(EMC)--第4-16部分:试验和测量技术--在0Hz-150kHz频率范围内的传导共模骚扰的抗扰度试验Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 k IEC 61000-4-16-2015电磁兼容(EMC)--第4-16部分:试验和测量技术--在0Hz-150kHz频率范围内的传导共模骚扰的抗扰度试验Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 k

IEC 61000-4-16-2015电磁兼容(EMC)--第4-16部分:试验和测量技术--在0Hz-150kHz频率范围内的传导共模骚扰的抗扰度试验Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 k

  • 标准类别:
  • 标准大小:
  • 标准编号:IEC 61000-4-16-2015
  • 标准状态:现行
  • 更新时间:2023-04-18
  • 下载次数:
标准简介

This part of IEC 61000 relates to the immunity requirements and test methods for electrical and
electronic equipment to conducted, common mode disturbances in the range d.c. to 150 kHz.
The object of this standard is to establish a common and reproducible basis for testing
electrical and electronic equipment with the application of common mode disturbances to
power supply, control, signal and communication ports.
This standard defines
• test voltage and current waveform;
• range of test levels;
•  test equipment;
•  test set-up;
•  test procedures.
For some types of ports, for example ports intended to be used with highly balanced lines,
additional test provisions may be established by product committee specifications.
The test is intended to demonstrate the immunity of electrical and electronic equipment when
subjected to conducted, common mode disturbances such as those originating from power line
currents and return leakage currents in the earthing/grounding system.
The disturbances produced by 400 Hz mains systems are not included in the scope of this
standard.
Actual interference due to these disturbance phenomena is relatively rare, except in industrial
plants. Product committees should therefore consider whether there is a justification for
applying this standard in their product/product family standards (see also Clause 4).
This test is not relevant for equipment ports intended to be connected to short cables, having a
length less than 20 m or less.This part of IEC 61000 relates to the immunity requirements and test methods for electrical and
electronic equipment to conducted, common mode disturbances in the range d.c. to 150 kHz.
The object of this standard is to establish a common and reproducible basis for testing
electrical and electronic equipment with the application of common mode disturbances to
power supply, control, signal and communication ports.
This standard defines
• test voltage and current waveform;
• range of test levels;
•  test equipment;
•  test set-up;
•  test procedures.
For some types of ports, for example ports intended to be used with highly balanced lines,
additional test provisions may be established by product committee specifications.
The test is intended to demonstrate the immunity of electrical and electronic equipment when
subjected to conducted, common mode disturbances such as those originating from power line
currents and return leakage currents in the earthing/grounding system.
The disturbances produced by 400 Hz mains systems are not included in the scope of this
standard.
Actual interference due to these disturbance phenomena is relatively rare, except in industrial
plants. Product committees should therefore consider whether there is a justification for
applying this standard in their product/product family standards (see also Clause 4).
This test is not relevant for equipment ports intended to be connected to short cables, having a
length less than 20 m or less.
The immunity to harmonics and interharmonics, including mains signalling, on a.c. power ports (in differential mode) is not included in the scope of this standard and is covered by IEC 61000-4-13 and IEC 61000-4-19.
The immunity to conducted disturbances generated by intentional radio-frequency transmitters is not included in the scope of this standard and is covered by IEC 61000-4-6.dition 2.0 2015-12 REDLINE VERSION colour inside BASIC EMC PUBLICATION Electromagnetic compatibility (EMC) – Part 4-16: Testing and measurement techniques – Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz IEC 61000-4-16:2015-12 RLV(en) THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright ? 2015 IEC, Geneva, Switzerland All rights reserved. Unless ot

标准截图