首页 > 标准下载>IEC 60728-7-1-2015 电视信号、声音信号和交互式服务用电缆网络--第7-1部分:混合光纤同轴电缆室外设备状况监测--物理层规范 Cable networks for television signals, sound signals and interactive services - Part 7-1: Hybrid Fibre Coax Outside Plant status monitoring - Physical (PHY) layer specification免费下载
IEC 60728-7-1-2015 电视信号、声音信号和交互式服务用电缆网络--第7-1部分:混合光纤同轴电缆室外设备状况监测--物理层规范 Cable networks for television signals, sound signals and interactive services - Part 7-1: Hybrid Fibre Coax Outside Plant status monitoring - Physical (PHY) layer specification IEC 60728-7-1-2015 电视信号、声音信号和交互式服务用电缆网络--第7-1部分:混合光纤同轴电缆室外设备状况监测--物理层规范 Cable networks for television signals, sound signals and interactive services - Part 7-1: Hybrid Fibre Coax Outside Plant status monitoring - Physical (PHY) layer specification

IEC 60728-7-1-2015 电视信号、声音信号和交互式服务用电缆网络--第7-1部分:混合光纤同轴电缆室外设备状况监测--物理层规范 Cable networks for television signals, sound signals and interactive services - Part 7-1: Hybrid Fibre Coax Outside Plant status monitoring - Physical (PHY) layer specification

  • 标准类别:
  • 标准大小:
  • 标准编号:IEC 60728-7-1-2015
  • 标准状态:现行
  • 更新时间:2023-06-18
  • 下载次数:
标准简介

This part of IEC 60728 specifies requirements for The Hybrid Fibre Coax (HFC) Outside Plant
(OSP) Physical (PHY) Layer Specification and is part of the series of specifications developed
by the Hybrid Management Sub-Layer (HMS) subcommittee under the SCTE. The purpose of
the HMS specification is to support the design and implementation of interoperable
management systems for evolving HFC cable networks. The HMS Physical (PHY) Layer
Specification describes the physical layer portion of the protocol stack used for
communication between HMS-compliant transponders interfacing to managed outside plant
network elements (NE) and a centralized head-end element (HE). 
This standard describes the PHY layer requirements that must be implemented by all Type 2
and Type 3 compliant OSP HMS transponders on the HFC plant and the controlling equipment
in the head-end. Any exceptions to compliance with this standard will be specifically noted
herein as necessary. Refer to Table 1 for a full definition of the type classifications.
Electromagnetic Compatibility (EMC) is not specified in this standard and is left to the vendor
to ensure compliance with local EMC regulatory requirements. Other than operating
temperature, physical parameters such as shock, vibration, humidity, etc., are also not
specified and left to the vendor’s discretion.dition 1.1 2015-04 CONSOLIDATED VERSION colour inside Cable networks for television signals, sound signals and interactive services – Part 7-1: Hybrid Fibre Coax Outside Plant status monitoring – Physical (PHY) Layer Specification IEC 60728-7-1:2003-10+AMD1:2015-04 CSV(en) THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright ? 2015 IEC, Geneva, Switzerland All rights reserved. Unless otherwise specif

标准截图
下一条:返回列表
版权:如无特殊注明,文章转载自网络,侵权请联系cnmhg168#163.com删除!文件均为网友上传,仅供研究和学习使用,务必24小时内删除。