首页 > 标准下载>ASTM D7315-2017 测定静态模式下大于1个浊度单位(TU)的浊度的试验方法 Standard Test Method for Determination of Turbidity Above 1 Turbidity Unit (TU) in Static Mode免费下载
ASTM D7315-2017 测定静态模式下大于1个浊度单位(TU)的浊度的试验方法 Standard Test Method for Determination of Turbidity Above 1 Turbidity Unit (TU) in Static Mode ASTM D7315-2017 测定静态模式下大于1个浊度单位(TU)的浊度的试验方法 Standard Test Method for Determination of Turbidity Above 1 Turbidity Unit (TU) in Static Mode

ASTM D7315-2017 测定静态模式下大于1个浊度单位(TU)的浊度的试验方法 Standard Test Method for Determination of Turbidity Above 1 Turbidity Unit (TU) in Static Mode

  • 标准类别:
  • 标准大小:
  • 标准编号:ASTM D7315-2017
  • 标准状态:现行
  • 更新时间:2023-08-01
  • 下载次数:
标准简介

1.1 This test method covers the static determination of turbidity in water. Static refers to a sample that is removed from its source and tested in an isolated instrument. (See Section 4.) 1.2 This test method is applicable to the measurement of turbidities greater than 1.0 turbidity unit (TU). The upper end of the measurement range was left undefined because different technologies described in this test method can cover very different ranges. The round robin study covered the range of 0–4000 turbidity units because instrument verification in this range can typically be covered by standards that can be consistently reproduced. 1.3 Many of the turbidity units and instrument designs covered in this test method are numerically equivalent in calibration when a common calibration standard is applied across those designs listed in Table 1. Measurement of a common calibration standard of a defined value will also produce equivalent results across these technologies. TABLE 1 Summary of Known Instrument Designs, Applications, Ranges, and Reporting Units Design and Reporting Unit Prominent Application Key Design Features Typical Instrument Range Suggested Application Ranges Nephelometric non-ratio (NTU) White light turbidimeters. Comply with U.S. EPA Method 180.1 for low level turbidity monitoring. Detector centered at 90° relative to the incident light beam. Uses a white light spectral source. 0.0–40 0.0–40 Regulatory Ratio White Light turbidimeters (NTRU) Complies with ISWTR regulations and Standard Method 2130B. Can be used for both low and high level measurement. Used a white light spectral source. Primary detector centered at 90°. Other detectors located at other angles. An instrument algorithm uses a combination of detector readings to generate the turbidity reading. 0–10 000 0–40 Regulatory 0–10 000 other Nephelometric, near-IR turbidimeters, non-ratiometric

标准截图
下一条:返回列表
版权:如无特殊注明,文章转载自网络,侵权请联系cnmhg168#163.com删除!文件均为网友上传,仅供研究和学习使用,务必24小时内删除。