首页 > 标准下载>ASTM C591-2017 预制未光面硬质蜂窝状聚异氰脲酸酯隔热材料规格 Standard Specification for Unfaced Preformed Rigid Cellular Polyisocyanurate Thermal Insulation免费下载
ASTM C591-2017 预制未光面硬质蜂窝状聚异氰脲酸酯隔热材料规格 Standard Specification for Unfaced Preformed Rigid Cellular Polyisocyanurate Thermal Insulation ASTM C591-2017 预制未光面硬质蜂窝状聚异氰脲酸酯隔热材料规格 Standard Specification for Unfaced Preformed Rigid Cellular Polyisocyanurate Thermal Insulation

ASTM C591-2017 预制未光面硬质蜂窝状聚异氰脲酸酯隔热材料规格 Standard Specification for Unfaced Preformed Rigid Cellular Polyisocyanurate Thermal Insulation

  • 标准类别:
  • 标准大小:
  • 标准编号:ASTM C591-2017
  • 标准状态:现行
  • 更新时间:2023-08-05
  • 下载次数:
标准简介

1.1 This specification covers the types, physical properties, and dimensions of unfaced, preformed rigid cellular polyisocyanurate plastic material intended for use as thermal insulation on surfaces from -297°F (-183°C) to 300°F (149°C). For specific applications, the actual temperature limits shall be agreed upon by the manufacturer and purchaser. 1.2 This specification only covers “polyurethane modified polyisocyanurate” thermal insulation which is commonly referred to as “polyisocyanurate” thermal insulation. This standard does not encompass all polyurethane modified materials. Polyurethane modified polyisocyanurate and other polyurethane materials are similar, but the materials will perform differently under some service conditions. 1.3 This standard is designed as a material specification, not a design document. Physical property requirements vary by application and temperature. At temperatures below -70°F (-51°C) the physical properties of the polyisocyanurate insulation at the service temperature are of particular importance. Below -70°F (-51°C) the manufacturer and the purchaser must agree on what additional cold temperature performance properties are required to determine if the material can function adequately for the particular application. 1.4 This standard addresses requirements of unfaced preformed rigid cellular polyisocyanurate thermal insulation manufactured using blowing agents with an ozone depletion potential of 0 (ODP 0). 1.5 When adopted by an authority having jurisdiction, codes that address fire properties in many applications regulate the use of the thermal insulation materials covered by this specification. Fire properties are controlled by job, project, or other specifications where codes or government regulations do not apply. 1.6 The values stated in inch-pound units are to be regarded as standard. The values

标准截图
下一条:返回列表
版权:如无特殊注明,文章转载自网络,侵权请联系cnmhg168#163.com删除!文件均为网友上传,仅供研究和学习使用,务必24小时内删除。