IEC 61970-452-2015 能量管理系统应用程序接口(EMS-API)--第452部分:通用信息模型(CIM)静态传输网络替代标准模型协议集 Energy management system application program interface (EMS-API) - Part 452: CIM model exchange specification
- 标准类别:
- 标准大小:
- 标准编号:IEC 61970-452-2015
- 标准状态:现行
- 更新时间:2023-08-23
- 下载次数:次
This part of IEC 61970 is a member of the IEC 61970-450 to -499 series that, taken as a whole, defines at an abstract level the content and exchange mechanisms used for data transmitted between control centers and/or control center components.
The purpose of this document is to rigorously define the subset of classes, class attributes, and roles from the CIM necessary to execute state estimation and power flow applications. The North American Electric Reliability Council (NERC) Data Exchange Working Group (DEWG) Common Power System Modeling group (CPSM) produced the original data requirements, which are shown in Annex C. These requirements are based on prior industry practices for exchanging power system model data for use primarily in planning studies. However, the list of required data has been extended to facilitate a model exchange that includes parameters common to breaker-oriented applications. Where necessary this document establishes conventions, shown in Clause 5, with which an XML data file must comply in order to be considered valid for exchange of models.
This document is intended for two distinct audiences, data producers and data recipients, and may be read from two perspectives.
From the standpoint of model export software used by a data producer, the document describes a minimum subset of CIM classes, attributes, and associations which must be present in an XML formatted data file for model exchange. This standard does not dictate how the network is modelled, however. It only dictates what classes, attributes, and associations are to be used to describe the source model as it exists. All classes, attributes, and associations not explicitly labeled as recommended or conditionally required should be considered required with the following caveat. Consider, as an example, the situation in which an exporter produces an XML data file describing a small section of the exporter’s network that happens to contain no breakers. The resulting XML data file should, therefore, not contain an instance of the Breaker class. On the other hand, if the section of the exporter’s network does contain breakers, the resulting data file should contain instances of the Breaker class that include, at a minimum, the attributes and roles described herein for Breakers. Furthermore, it should be noted that an exporter may, at his or her discretion, produce an XML data file containing additional class data described by the CIM RDF Schema but not required by this document provided these data adhere to the conventions established in Clause 5.
From the standpoint of the model import used by a data recipient, the document describes a subset of the CIM that importing software must be able to interpret in order to import exported models. As mentioned above, data providers are free to exceed the minimum requirements described herein as long as their resulting data files are compliant with the CIM RDF Schema and the conventions established in Clause 5. The document, therefore, describes additional classes and class data that, although not required, exporters will, in all likelihood, choose to include in their data files. The additional classes and data are labeled as recommended or as not required to distinguish them from their required counterparts. Please note, however, that data importers could potentially receive data containing instances of any and all classes described by the CIM RDF Schema.dition 2.0 2015-04
INTERNATIONAL
STANDARD
colour
inside
Energy management system application program interface (EMS-API) –
Part 452: CIM model exchange specification
IEC 61970-452:2015-04(en)
THIS PUBLICATION IS COPYRIGHT PROTECTED
Copyright ? 2015 IEC, Geneva, Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by
-
GB 30871-2022免费下载危险化学品企业特殊作业安全规范 2023-08-23
-
GB/T 1094.1-2013电力变压器 第1部分:总则 2023-08-23
-
GB/T 706-2016热轧型钢 2023-08-23
-
JB/T 10216-2013电控配电用电缆桥架 2023-08-23
-
GB 9706.1-2020医用电气设备 第1部分:基本安全和基本性能的通用要求 2023-08-23
-
GB/T 10801.2-2018绝热用挤塑聚苯乙烯泡沫塑料(XPS) 2023-08-23
-
GB 51251-2017建筑防烟排烟系统技术标准 2023-08-23
-
GB/T 13663.2-2018给水用聚乙烯(PE)管道系统 第2部分:管材 2023-08-23