

IEC TR 60919-1-2017 带有电网换相换流器的高压直流(HVDC)系统的性能--第1部分:稳态条件 Performance of high-voltage direct current (HVDC) systems with line-commutated converters-Part 1: Steady-state conditions
- 标准类别:
- 标准大小:
- 标准编号:IEC TR 60919-1-2017
- 标准状态:现行
- 更新时间:2023-10-14
- 下载次数:次
This part of the IEC 60919 provides general guidance on the steady-state performance requirements of high-voltage direct current (HVDC) systems. It concerns the steady-state performance of two-terminal HVDC systems utilizing 12-pulse converter units comprised of three-phase bridge (double- way) connections (see Figure 1), but it does not cover multi- terminal HVDC transmission systems. Both terminals are assumed to use thyristor valves as the main semiconductor valves and to have power flow capability in both directions. Diode valves are not considered in this report.Only line-commutated converters are covered in this report, which includes capacitor commutated converter circuit configurations. General requirements for semiconductor line- commutated converters are given in IEC 60146-1-1, IEC/TR 60146-1-2 and IEC 60146-1-3. Voltage-sourced converters are not considered. This technical report, which covers steady-state performance, is followed by additional documents on dynamic performance and transient performance. All three aspects should be considered when preparing two-terminal HVDC system specifications. The difference between system performance specifications and equipment design specifications for individual components of a system should be realized. Equipment specifications and testing requirements are not defined in this report. Also excluded from this report are detailed seismic performance requirements. In addition, because there are many variations between different possible HVDC systems, this report does not consider these in detail; consequently, it should not be used directly as a specification for a particular project, but rather to provide the basis for an appropriate specification tailored to fit actual system requirements.Frequently, performance specifications are prepared as a single package for the two HVDC substations in a particular system. Alternatively, some parts of the HVDC system can be separately specified and purchased. In such cases, due consideration should be given to co- ordination of each part with the overall HVDC system performance objectives and the interface of each with the system should be clearly defined. Typical of such parts, listed in the appropriate order of relative ease for separate treatment and interface definition, are: a) d.c. line, electrode line and earth electrode; b) telecommunication system; c) converter building, foundations and other civil engineering work; d) reactive power supply including a.c. shunt capacitor banks, shunt reactors, synchronous and static reactive power (VAR) compensators; e) a.c. switchgear; f) d.c. switchgear; g) auxiliary systems; h) a.c. filters; i) d.c. filters; j) d.c. reactors; k) converter transformers; l) surge arresters; m) series commutation capacitors; n) valves and their ancillaries; o) control and protection systems.NOTE The last four items are the most difficult to separate, and, in fact, separation of these four may be inadvisable. A complete steady-state performance specification for a HVDC system should consider Clauses 3 to 21 of this report. Terms and definitions for high-voltage direct current (HVDC) transmission used in this report are given in IEC 60633. Since the equipment items are usually separately specified and purchased, the HVDC transmission line, earth electrode line and earth electrode (see Clause 10) are included only because of their influence on the HVDC system performance. For the purpose of this report, an HVDC substation is assumed to consist of one or more converter units installed in a single location together with buildings, reactors, filters, reactive power supply, control, monitoring, protective, measuring and auxiliary equipment. While there is no discussion of a.c. switching substations in this report, a.c. filters and reactive power sources are included, although they may be connected to an a.c. bus separate from the HVDC substation, as discussed in Clause 16.dition 3.2 2017-05 CONSOLIDATED VERSION colour inside Performance of high-voltage direct current (HVDC) systems with line- commutated converters – Part 1: Steady-state conditions IEC TR 60919-1:2010-05+AMD1:2013-04+AMD2:2017-05 CSV(en) THIS PUBLICATION IS COPYRIGHT PROTECTED Copyright ? 2017 IEC, Geneva, Switzerland All rights reserved. Unless otherwise specified, no part of this publication may
-
GB 30871-2022免费下载危险化学品企业特殊作业安全规范 2023-10-14
-
GB/T 1094.1-2013电力变压器 第1部分:总则 2023-10-14
-
GB/T 706-2016热轧型钢 2023-10-14
-
JB/T 10216-2013电控配电用电缆桥架 2023-10-14
-
GB 9706.1-2020医用电气设备 第1部分:基本安全和基本性能的通用要求 2023-10-14
-
GB/T 10801.2-2018绝热用挤塑聚苯乙烯泡沫塑料(XPS) 2023-10-14
-
GB/T 13663.2-2018给水用聚乙烯(PE)管道系统 第2部分:管材 2023-10-14
-
GB 51251-2017建筑防烟排烟系统技术标准 2023-10-14