

ISO/TS 20177-2018 真空技术--真空压力表--测量和报告排气速度的程序 Vacuum technology — Vacuum gauges — Procedures to measure and report outgassing rates
- 标准类别:
- 标准大小:
- 标准编号:ISO/TS 20177-2018
- 标准状态:现行
- 更新时间:2023-12-17
- 下载次数:次
This document describes procedures to measure outgassing rates from components designed for vacuum chambers and of vacuum chambers as a whole. The outgassing rates are expected to be lower
than 10−5 Pa m3 s−1 (10−2 Pa L s−1 ) at 23 °C and to emerge from devices that are suitable for high or ultra-high vacuum applications. The molecular mass of the outgassing species or vapour is below 300 u.
The upper limit 10−5 Pa m3 s−1 of total outgassing rate is specified independent of the size, the total surface area and texture or state of the outgassing material. If a specific outgassing rate (outgassing rate per area) is determined, the area is not a specific surface area including the surface roughness, but the nominal geometrical one. When it is difficult to determine the nominal geometrical surface area of the sample, such as powders, porous materials, very rough surfaces, or complex devices, mass specific outgassing rate (e.g. outgassing rate per gram) is used.
For many practical applications, it is sufficient to determine the total outgassing rate. If a measuring instrument, which sensitivity is gas species dependent, is used, the total outgassing rate are given in nitrogen equivalent. In cases, however, where the total outgassing rate is too high, the disturbing gas species is identified, and its outgassing rate is measured in order to improve the sample material. This document covers both cases.
Some outgassing molecules can adsorb on a surface with a residence time that is much longer than the total time of measurement. Such molecules cannot be detected by a detecting instrument when there is no direct line of sight. This is considered as a surface effect and surface analytical investigations are more useful than general outgassing rate measurements considered here. Also, molecules that are released from the surface by irradiation of UV light or X-rays, are out of the scope of this document.
This document is written to standardize the measurement of outgassing rates in such a way that values obtained at different laboratories and by different methods are comparable. To this end, for any of the described methods, traceability is provided to the System International (SI) for the most important parameters of each method and according to the metrological level.
Outgassing rate measurements by mass loss, which were mainly developed for testing of spacecraft and satellite materials, are not gas specific. For acceptable measurement times, mass loss measurements
require significantly higher outgassing rates (>10−5 Pa m3 s−1 ) than typical for high and ultrahigh vacuum components. Also, it is not possible to measure the sample in situ due to the weight of the vacuum chamber, since the balances are not vacuum compatible. For these reasons, mass loss measurements are not considered in this document.
It is assumed that the user of this document is familiar with high and ultra-high vacuum technology and the corresponding measuring instrumentation such as ionization gauges and quadrupole mass spectrometers.st edition
2018-06
Vacuum technology — Vacuum gauges
— Procedures to measure and report
outgassing rates
Technique du vide — Manomètres à vide — Méthodes de mesurage et
de rapport du taux de dégagement de gaz
Reference number
ISO/TS 20177:2018(E)
?
ISO 2018
ISO/TS 20177:2018(E)
COPYRIGHT PROTECTED DOCUMENT
? ISO 2018
All rights reserved. Unless othe
-
GB 30871-2022免费下载危险化学品企业特殊作业安全规范 2023-12-17
-
GB/T 706-2016热轧型钢 2023-12-17
-
GB/T 1094.1-2013电力变压器 第1部分:总则 2023-12-17
-
JB/T 10216-2013电控配电用电缆桥架 2023-12-17
-
GB 9706.1-2020医用电气设备 第1部分:基本安全和基本性能的通用要求 2023-12-17
-
GB/T 13663.2-2018给水用聚乙烯(PE)管道系统 第2部分:管材 2023-12-17
-
GB/T 10801.2-2018绝热用挤塑聚苯乙烯泡沫塑料(XPS) 2023-12-17
-
GB 51251-2017建筑防烟排烟系统技术标准 2023-12-17
-
YB/T 4001.1-2019钢格栅板及配套件 第1部分:钢格栅板 2023-12-17