Performance and Optimization for a Ground-Coupled Liquid Loop Heat Recovery Ventilation System Performance and Optimization for a Ground-Coupled Liquid Loop Heat Recovery Ventilation System

Performance and Optimization for a Ground-Coupled Liquid Loop Heat Recovery Ventilation System

  • 期刊名字:东华大学学报(英文版)
  • 文件大小:
  • 论文作者:ZHOU Ya-su,Per FAHLEN,Torbjrn
  • 作者单位:Department of Building Environment and Equipment Engineering,Per FAHLEN
  • 更新时间:2023-02-07
  • 下载次数:
论文简介

Ground-coupled heat pumps(GCHP) arecommonly used in residential heating system. To mitigatethe boreholes temperature dropping with operating time, anew exhaust-air recharging system is developed. The newrecharging system can be used in three operational modes.In this paper, a ground-coupled heat recovery ventilation(HRV) model is discussed. A thermal model is set up tofind the optimal brine flow rate and heat transfer allocationratio between exhaust and supply coils for maximum heatrecovery efficiency. Contrary to the conventional liquid-loopHRV systems, the brine temperature entering the exhaustcoil never goes blow zero(0℃), and hence defrosting isneedless in the ground-coupled HRV system. This can makethe ground-coupled HRV system over 20% more efficientthan a conventional HRV system at low outdoortemperatures.