IEC 62629-12-1-2014 3D显示器--第12-1部分:戴眼镜式立体显示测量方法--光学 3D Display devices – Part 12-1: Measuring methods for stereoscopic displays using glasses – Optical
- 标准类别:
- 标准大小:
- 标准编号:IEC 62629-12-1-2014
- 标准状态:现行
- 更新时间:2023-09-27
- 下载次数:次
This part of IEC 62629 determines the following measuring methods for characterizing the performance of stereoscopic display devices using either active or passive glasses.
This standard focuses on the types of stereoscopic displays using glasses as follows:
The types of stereoscopic displays reproducing temporally interlaced images and applicable glasses are:
– displays representing temporally interlaced (high frame rate) images and active glasses (time dividing shutter glasses), and
– displays with front screen switchable polarizer representing temporally interlaced images and linear or circular polarizer passive glasses.
The types of stereoscopic displays reproducing spatially interlaced images and applicable glasses are: – displays with patterned retarder representing spatially interlaced images and linear or circular polarizer passive glasses. Some parts of these measuring methods may also be applied to other types of stereoscopic displays using glasses not listed above.
The measuring items for the sets of stereoscopic display and glasses are as follows:
a) luminance,
b) luminance uniformity,
c) interocular luminous difference,
d) dark-room contrast ratio,
e) interocular contrast difference,
f) colour gamut,
g) white chromaticity,
h) white chromatic uniformity,
i) interocular chromatic difference,
j) interocular crosstalk, and
k) interocular crosstalk screen position dependency (interocular crosstalk uniformity).
The measuring parameters are as follows:
l) viewing direction dependency,
m) dependency on in-plane rotation of lens, n) dependency on tilt angle of lens, and
o) viewing distance dependency.
The measuring items for the glasses are as follows:
p) transmittance (open state),
q) extinction ratio,
r) colour shift (open state, on-state),
s) interocular transmittance,
t) interocular contrast difference,
u) interocular chromatic difference,
v) response time (open state to/from closed state) of active glasses, and
w) uniformity of lens. The measuring parameters are as follows:
x) angular characteristic, and
y) temperature dependency.dition 1.0 2014-01
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
3D Display devices –
Part 12-1: Measuring methods for stereoscopic displays using glasses – Optical
Dispositifs d'affichage 3D –
Partie 12-1: Méthodes de mesure pour les écrans stéréoscopiques utilisant des
lunettes – Optique
IEC 62629-12-1:2014
THIS PUBLICATION IS COPYRIGHT PROTECTED
Copyright ? 2008 IEC, Geneva, Switzerland
All rights reserved. Unless otherwise
-
GB 30871-2022免费下载危险化学品企业特殊作业安全规范 2023-09-27
-
GB/T 1094.1-2013电力变压器 第1部分:总则 2023-09-27
-
GB/T 706-2016热轧型钢 2023-09-27
-
JB/T 10216-2013电控配电用电缆桥架 2023-09-27
-
GB 9706.1-2020医用电气设备 第1部分:基本安全和基本性能的通用要求 2023-09-27
-
GB/T 10801.2-2018绝热用挤塑聚苯乙烯泡沫塑料(XPS) 2023-09-27
-
GB/T 13663.2-2018给水用聚乙烯(PE)管道系统 第2部分:管材 2023-09-27
-
GB 51251-2017建筑防烟排烟系统技术标准 2023-09-27